100 plates each 2m wide x 1.5m long at 55° Total plate area = (100 \times 3 = 300 m²) Projected area = (300 \times \sin(55°) \approx 300 \times 0.819 = 245.7 m²)

to minimize the distance a particle must travel to hit a collection surface Step-by-Step Design Calculations lamella clarifier design calculation pdf downloadl better

The sludge zone must be designed to collect settled particles without allowing them to be re-entrained by the incoming water flow. 100 plates each 2m wide x 1